Low price and high reliability
105¡æ output capacitor
¡¡
AC input power suitable for the world
¡¡
High efficiency and low operation
temperature
¡¡
Soft-start current can reduce the AC
input impact effectively
¡¡
With short-circuit and
overload
protection
¡¡
100% full-load burning test
¡¡
Installed with EMI
filter, minimum wave
|
|
¡¡ |
Model
¡¡
Performance |
SP-500-12 |
SP-500-13.5 |
SP-500-15 |
SP-500-24 |
SP-500-27 |
SP-500-48 |
DC output voltage |
12V |
13.5V |
15V |
24V |
27V |
48V |
Output voltage error(Note:2) |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
Rated output current |
40A |
36A |
32A |
20A |
18A |
10A |
Output current rage |
0-40A |
0-36A |
0-32A |
0-20A |
0-18A |
0-10A |
Wave and noise(Note:3) |
240mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
200mVp-p |
300mVp-p |
Inlet stability(Note:4) |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
Load stability(Note:5) |
¡À1% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
DC output power |
480W |
486W |
480W |
480W |
486W |
480W |
Efficiency |
84% |
84% |
83% |
85.5% |
86.5% |
87% |
Adjustable range for DC voltage |
10-13.2V |
12-15V |
13.5-18V |
20-26.4V |
24-30V |
41-56V |
Range for input
voltage |
88~132VAC/176~264VAC BY SWITCH
47~63Hz;124~370VDC |
Input current |
7A/115V 3.5A/230V |
Impact current |
18A/115V 36A/230V |
Leakage current |
<3.5mA/240VAC |
Overload protection |
105%¡«135% TYPE Foldback Cut off
output RESET:Self-Reset |
Over-voltage protection |
13.8~16.2V
|
15.5~18.2V
|
18~21V
|
27.6~32.4V
|
31~36.5V
|
57.6~67.2V
|
High-temperature protection |
RTH1 OR RTH2>=50¡æ FAN ON,<=45¡æ FAN
OFF,>=70¡æ Cut off output |
Temperature factor |
¡À0.03%¡æ(0~50¡æ) |
Start, rise and lock time |
1.5s,50ms,20ms |
Vibration resistance |
10~500Hz,2G
10min./1cycle,time60,minutes for each shaft |
Resistance to pressure |
Input and output
internal:1.5KVAC,Input and enclosure:1.5KVAC,Output
and enclosure:0.5KVAC |
Isolation resistance |
Input and output
internal, input and
enclosure, Output and enclosure:500VAC/100M Ohms |
Operating temperature and humidity |
-10¡æ~+50¡æ,20%~90%RH |
Store temperature and humidity |
-20¡æ~+85¡æ,10%~95%%RH |
Overall dimension |
185*20*93mm
|
Weight |
1.8Kgs |
Safety standard
|
DESIGN REFER TO UL1950 TUV EN60950 |
EMC standard |
DESIGN REFER IEC1000-42,3,4,5,6,8,11
IEC100-3-2 |
Note:1.The testing condition for the
parameter above is :230VAC input, rated load, 25¡æ
70% RH.Humidity
¡¡¡¡ 2.Error.include the setting error, line stability
and load stability.(Note:5)
¡¡¡¡ 3.Wave test: adopting A12" double wire for 20MHz,
and 0.1UF&47UF capacitor short-circuit for
interrupting.
¡¡¡¡ 4.Inlet voltage stability test: when is over load,
the lowest voltage of inlet is up to the highest
voltage.
¡¡¡¡ 5.Load stability test: The load is from 0% to 100%
¡¡¡¡ 6.C3,4 must be knocked down. |