AC-DC SINGLE OUTPUT   PAGE1   PAGE2   PAGE3    PAGE4   PAGE5   PAGE6

S-40 SERIES
¡¡
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter, minimum wave
  • ¡¡

    Model

    ¡¡
    Performance
    S-40-5 S-40-12 S-40-15 S-40-24
    DC output voltage 5V 12V 15V 24V
    Output voltage error(Note:2) ¡À2% ¡À1% ¡À1% ¡À1%
    Rated output current 8A 3.5A 2.8A 1.8A
    Output current rage 0-8A 0-3.5A 0-2.8A 0-1.8A
    Wave and noise(Note:3) 75mVp-p 100mVp-p 100mVp-p 100mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.3% ¡À0.2%
    Load stability(Note:5) ¡À1% ¡À0.5% ¡À0.5% ¡À0.5%
    DC output power 40W 42.2W 42W 43W
    Efficiency 72%/115VAC 76%/115VAC 76%/115VAC 78%/115VAC
    Adjustable range for DC voltage +10,-5% ¡À10% ¡À10% ¡À10%
    Range for input voltage 85~264VAC/47~63VAC;120~370VDC
    Input current 1.2A/115V 0.6A/230V
    Impact current Cool-start current35A/115V 60A/230V
    Leakage current <1mA/240VAC
    Overload protection 105%~150% TYPE: PULSING HICCUP SHUTDOWN RESET:self-reset
    Over-voltage protection 115%~135%
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start, rise and lock time 800ms,50ms,20ms/115VAC 300ms,50ms,80ms/230VAC
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure Input and output internal:3KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 129*98*38mm
    Weight 0.45Kgs
    Safety standard Meet UL1012,TUV EN60950
    EMC standard Conform to IEC801-2,3,4,IEC555-2
    Note:1.The testing condition for the parameter above is :230VAC input, rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error, line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test: adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test: The load is from 0% to 100%
    ¡¡¡¡ 6.C2,3,6 must be knocked down.
    S-50 SERIES
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter, minimum wave
  • Model

    ¡¡
    Performance
    S-50-5 S-50-12 S-50-15 S-50-24
    DC output voltage 5V 12V 15V 24V
    Output voltage error(Note:2) ¡À2% ¡À1% ¡À1% ¡À1%
    Rated output current 10A 4.2A 3.4A 2.1A
    Output current rage 0-10A 0-4.2A 0-3.4A 0-2.1A
    Wave and noise(Note:3) 75mVp-p 100mVp-p 100mVp-p 100mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5%
    Load stability(Note:5) ¡À1% ¡À0.5% ¡À0.5% ¡À0.5%
    DC output power 50W 50.4W 50.4W 50.4W
    Efficiency 71% 78% 78% 82%
    Adjustable range for DC voltage ¡À10,-5% ¡À10% ¡À10% ¡À10%
    Range for input voltage 85~132VAC/170~264VACswitch choice
    Input current 1.3A/115V 0.45A/230V
    Impact current Cool-start current18A/115V 36A/230V
    Leakage current <0.5mA/240VAC
    Overload protection 105%~150%Model:FOLDBACK:current limit reset: self-reset
    Over-voltage protection ¡­¡­
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start, rise and lock time 200ms,100ms,30ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:0500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 159*97*38mm
    Weight 0.5Kgs
    Safety standard Conform to requirement in UL1012
    EMC standard ¡­¡­
    Note:1.The testing condition for the parameter above is :230VAC input, rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error, line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test: adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test: The load is from 0% to 100%
    S-60 SERIES
    ¡¡
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter, minimum wave
  • ¡¡

    Model

    ¡¡
    Performance
    S-60-5 S-60-12 S-60-15 S-60-24
    DC output voltage 5V 12V 15V 24V
    Output voltage error(Note:2) ¡À2% ¡À1% ¡À1% ¡À1%
    Rated output current 12A 5A 2.8A 1.8A
    Output current rage 0-12A 0-5A 0-2.8A 0-1.8A
    Wave and noise(Note:3) 120mVp-p 120mVp-p 150mVp-p 150mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.4% ¡À0.25%
    Load stability(Note:5) ¡À1% ¡À0.5% ¡À0.5% ¡À0.5%
    DC output power 60W 60W 60W 60W
    Efficiency 73% 76% 77% 79%
    Adjustable range for DC voltage +10,-5% ¡À10% ¡À10% ¡À10%
    Range for input voltage 85~264VAC/47~63Hz;120~370VDC
    Input current 2A/115V 1A/230V
    Impact current Cool-start current 30A/115V 60A/230V
    Leakage current <3.5mA/240VAC
    Overload protection 105%~150% TYPE: PULSING HICCUP SHUTDOWN RESET: reset: self-reset
    Over-voltage protection 115%~135%
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start, rise and lock time 800ms,50ms,20ms/115VAC 300ms,50ms,80ms/230VAC
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure Input and output internal:3KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 159*97*38mm
    Weight 0.55Kgs
    Safety standard Meet UL1012,TUV EN60950
    EMC standard Conform to IEC801-2,3,4,IEC555-2
    Note:1.The testing condition for the parameter above is :230VAC input, rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error, line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test: adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test: The load is from 0% to 100%
    ¡¡¡¡ 6.C2,3,6 must be knocked down.

    AC-DC SINGLE OUTPUT   PAGE1   PAGE2   PAGE3    PAGE4   PAGE5   PAGE6