Low price and high reliability
105¡æ output capacitor
¡¡
AC input power suitable for the world
¡¡
High efficiency and low operation
temperature
¡¡
Soft-start current can reduce the AC
input impact effectively
¡¡
With short-circuit and
overload
protection
¡¡
100% full-load burning test
¡¡
Installed with EMI
filter, minimum wave
|
|
|
Model
¡¡
Performance |
S-100F-5 |
S-100F-7.5 |
S-100F-12 |
S-100F-15 |
S-100F-24 |
S-100-48 |
DC output voltage |
5V |
7.5V |
12V |
15V |
24V |
48V |
Output voltage error(Note:2) |
¡À2% |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
Rated output current |
20A |
13.5A |
8.5A |
6.7A |
4.5A |
2.2A |
Output current rage |
0-20A |
0-13.5A |
0-8.5A |
0-6.7A |
0-4.5A |
0-2.2A |
Wave and noise(Note:3) |
100mVp-p |
125mVp-p |
125mVp-p |
125mVp-p |
150mVp-p |
150mVp-p |
Inlet stability(Note:4) |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
Load stability(Note:5) |
¡À1% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
DC output power |
100W |
101W |
102W |
100.5W |
108W |
105.6W |
Efficiency |
76% |
76% |
80% |
81% |
83% |
84% |
Adjustable range for DC voltage |
+10% |
¡À10% |
¡À10% |
¡À10% |
¡À10% |
¡À10% |
Range for input
voltage |
85~132VAC/176~264VAC SELECTED BY
JUMPER OR SWITCH 47~63Hz;255~370VDC |
Input current |
2.4A/115V 1.2A/230V |
Impact current |
Cool-start current 35A/115V 60A/230V |
Leakage current |
<1mA/240VAC |
Overload protection |
105%~150%
TYPE: PULSING HICCUP
SHUTDOWN RESET: reset:self-reset |
Over-voltage protection |
115%~135% |
High-temperature protection |
¡¡ |
Temperature factor |
¡À0.03%¡æ(0~50¡æ) |
Start, rise and lock time |
1ms,30ms,15ms |
Vibration resistance |
10~500Hz,2G
10min./1cycle,time60,minutes for each shaft |
Resistance to pressure |
Input and output
internal:3KVAC,Input and enclosure:1.5KVAC,Output
and enclosure:0.5KVAC |
Isolation resistance |
Input and output
internal, input and
enclosure, Output and enclosure:500VAC/100M Ohms |
Operating temperature and humidity |
-10¡æ~+60¡æ£¬20%~90%RH |
Store temperature and humidity |
-20¡æ~+85¡æ,10%~95%RH |
Overall dimension |
199*98*38mm
|
Weight |
0.65Kgs |
Safety standard
|
Meet UL1012,TUV EN60950 |
EMC standard |
Conform to IEC801-2,3,4,IEC555-2 |
Note:1.The testing condition for the
parameter above is :230VAC input, rated load, 25¡æ
70% RH.Humidity
¡¡¡¡ 2.Error.include the setting error, line stability
and load stability.(Note:5)
¡¡¡¡ 3.Wave test: adopting A12" double wire for 20MHz,
and 0.1UF&47UF capacitor short-circuit for
interrupting.
¡¡¡¡ 4.Inlet voltage stability test: when is over load,
the lowest voltage of inlet is up to the highest
voltage.
¡¡¡¡ 5.Load stability test: The load is from 0% to 100%
¡¡¡¡ 6.C3,4,32 must be knocked down. |