SV-2Q Automobile Tail Gas Analyzer
Brief introduction:
SV-2Q automobile tail gas analyzer was designed by world-leading
technology, with high light LED screen. The analyzer has the
function of automatic zero adjustment alarm for each half hour, and
it also can be connected with computer through the RS-232 plug.
SV-2Q can test the tail gas from the automobiles use liquefied
petroleum gas or compressed natural gas as fuel, so it is the best
choice of any kind of company of automobile repairing or control.
Main technical feature:
1. Measurement range:CO:0-10.0 10-2(%);
HC:0~10000 10-6(ppm);
2. Repetitiveness:¡Ü¡À2%;
3. Zero point floating: CO:¡À0.06 10-2(%)/1h;
HC:¡À30 10-6(ppm)/1h;
4. Crossing floating: Not over the permitted indicated error range
(1hour);
5. Indicated error: CO:¡À10%(relative error: 0-10%);
HC:¡À10%(relative error: 0-10000ppm);
6. Environmental condition:Temperature:0ºC-40ºC;
Humidity:¡Ü80%;
Atmospheric pressure:60-105kpa;
Power: AC 220V¡À10%, 50Hz¡À1Hz;
7. Preheat time:10 minutes ;
8. Display method: LED high light display;
9. Main functions: Connect with computer;
30 minutes automatic adjust to zero;
connect with outer printer |
SV-4Q Automobile Tail Gas Analyzer
Brief introduction:
SV-4Q automobile tail gas analyzer introduces in foreign advanced
technology and whole set of imported parts. It can analyze four
kinds of compositions in the tail gas, and has a high light LED
screen. The analyzer has the function of automatic zero adjustment
alarm for each half hour, and it can be connected with computer
through RS-232 plug, and also can print the test result by printer
connected. SV-4Q can test the tail gas from the automobiles use
liquefied petroleum gas or compressed natural gas as fuel, so it is
the best choice of the departments of police, traffic test station
and other automobile repair companies.
Main technical feature:
1. Measurement range:CO:0-10.0 10-2(%);
CO2:0-20.0 10-2(%);
HC:0-10000 10-6(ppm);
O2:0-25.0 10-2(%);
Petrol temperature:18ºC-150ºC;
Engine speed:100-20000rpm;
2. Repetitiveness:¡Ü¡À2%
3. Zero point floating: CO:¡À0.06 10-2(%)/1h;
CO2: ¡À0.5 10-2(%)/1h;
HC: ¡À30 10-6(ppm)/1h;
O2: ¡À0.5 10-2(%)/1h;
4. Crossing floating: Not over the permitted indicated error range
(1hour);
5. Indicated error: CO:¡À5%(relative error: 0-10%);
CO2:¡À5%(relative error: 0-20%);
HC:¡À5%(relative error: 0-4000ppm)¡À10%(relative error:
4001-10000ppm);
O2:¡À5%(relative error: 0-25%);
6. Environmental condition: Petrol temperature: ¡À2ºC(relative error)
Engine speed:¡À10%(relative error)
Temperature:0ºC-40ºC;
Humidity: ¡Ü80%;
Atmospheric pressure: 60-105kpa;
Power: AC 220V¡À10%, 50Hz¡À1Hz;
7. Preheat time:10 minutes;
8. Method of sample taking: Tail gas: Taking directly, and the
length of sample pipe and probe are 5M and 900mm;
Petrol temperature: Put the probe into the hole of lubricating oil
gauge of engine, and the length of probing is the length of oil
gauge. Then seal it with stopper in order to avoid the leakage of
oil. The pipe length is 5M;
Engine speed: The result is available at the point no more than 20cm
from the high voltage coil of engine;
9. Display method: LCD large screen display
10. Optional configuration: Gas temperature and engine speed;
11. Main features: Built-in printer, and computer network
communications, 30 minutes automatically suggest zero. Idle and
Idle-two measurement methods, plates imported functional group can
store 500 measurements, natural gas, liquefied petroleum gas and
petrol fuel three choices. |
SV-5Q Automobile Tail Gas Analyzer
Brief introduction:
SV-5Q automobile tail gas analyzer introduces in world-leading
foreign advanced technology and whole set of imported parts. It can
analyze five kinds of compositions in the tail gas, and has a large
liquid crystal display screen with whole Chinese menu. The analyzer
has the function of automatic zero adjustment alarm for each half
hour, and it can be connected with computer through RS-232 plug, and
there is a mini printer inside. SV-5Q can test the temperature of
the petrol and the speed of engine. The equipment can test the tail
gas from the automobiles use liquefied petroleum gas or compressed
natural gas as fuel, so it is the best choice of institutions of
environmental protection or scientific research and 3S, 4S station.
Main technical feature:
1. Measurement range:CO:0-10.0 10-2(%);
CO2 :0-20.0 10-2(%);
HC:0-10000 10-6(ppm);
O2 :0-25.0 10-2(%);
NO:0-5000 10-6(ppm);
Petrol temperature: 18ºC-150ºC;
Engine speed: 100-20000rpm;
2. Repetitiveness: ¡Ü¡À2%
3. Zero point floating: CO:¡À0.06 10-2(%)/1h;
CO2: ¡À0.5 10-2(%)/1h;
HC:¡À30 10-6(ppm)/1h;
O2: ¡À0.5 10-2(%)/1h;
NO: ¡À30 10-6(ppm)/1h;
4. Crossing floating: Not over the permitted indicated error range
(1hour);
5. Indicated error: CO:¡À5%(relative error: 0-10%);
CO2: ¡À5%(relative error: 0-20%);
HC:¡À5%(relative error: 0-4000ppm) ¡À10%(relative error:
4001-10000ppm);
O2: ¡À5%(relative error: 0-25%);
NO: ¡À5%(relative error: 0-5000ppm);
6. Environmental condition: Petrol temperature: ¡À2ºC(relative error)
Engine speed: ¡À1.0%(relative error)
Temperature:0ºC-40ºC;
Humidity:¡Ü80%;
Atmospheric pressure: 60-105kpa;
Power: AC 220V¡À10%, 50Hz¡À1Hz;
7. Preheat time:10 minutes;
8. Method of sample taking: Tail gas: Taking directly, and the
length of sample pipe and probe are 5M and 900mm;
Petrol temperature: Put the probe into the hole of lubricating oil
gauge of engine, and the length of probing is the length of oil
gauge. Then seal it with stopper in order to avoid the leakage of
oil. The pipe length is 5M;
Engine speed: The result is available at the point no more than 20cm
from the high voltage coil of engine;
9. Display method: LCD large screen display
10. Optional configuration: Gas temperature and engine speed;
11. Main features: Built-in printer, and computer network
communications, 30 minutes automatically suggest zero. Idle and
Idle-two measurement methods, plates imported functional group can
store 500 measurements, natural gas, liquefied petroleum gas and
petrol fuel three choices. |
SV-500A Exhaust Analyzer
Brief introduction:
¡ï Functional feature:
High accuracy, automatic calibration, automatic check automatically
HC residual checks to wash with pipeline system Automatic Cleaning
sampling pipeline, a variety of alternative measurement methods,
environmental temperature, humidity, atmospheric pressure, speed,
temperature and other parameters, GB/T 18285-2005 meet on the ASM-mode
test equipment requirements.
¡ï Use:
¡öApply to petrol vehicles steady loading conditions (ASM) emissions
testing system.
¡öApply to safety inspection station, test station and environmental
inspection stations and other stations.
¡öApply to all types of auto repair shop.
¡öApply to motor vehicles for factory new test, detection
application.
¡öApply to scientific research institutions, colleges and
universities to conduct research using laboratory.
Main technical feature:
1. Measurement Range:CO:0-15%; CO2:0-20%;
HC:0-10000ppm; O2:0-25%;
NO:0-5000ppm;
Petrol temperature :0ºC-150ºC;
Engine speed:0-20000rpm;
2. Zero point floating: CO:¡À0.06%; CO2:¡À0.2%;
HC:¡À20ppm; O2:¡À0.2%;
NO:¡À20ppm;
3.Resolution:CO:0.01%; CO2:0.1%;
HC:1ppm; O2:0.01%;
NO:1ppm;
Petrol temperature:0.1ºC;
Engine speed:1rpm;
4. Indicated error:
CO:¡À3%(0~10.00¡Á10-2(%)vol)¡À5%(10.01-15.00¡Á10-2(%)vol)
CO2:¡À3% (0~16.00¡Á10-2%)vol)¡À5%(16.01-20.00¡Á10-2(%)vol);
HC:¡À3%(0~2000¡Á10-6(ppm)vol)¡À5%
(2001~5000¡Á10-6(ppm)vol)¡À10%(5001~9999¡Á10-6(ppm)vol);
O2:¡À5%;
NO:¡À4%(0~4000¡Á10-6(ppm)vol)¡À8%(4000~5000¡Á10-6(ppm)vol);
Petrol temperature:¡À2ºC(absolute error);
Engine speed:¡À1.0%(relative error);
5. Display method: LCD large screen display;
6. Method of sample taking: Double sampling probe, respectively for
petrol and diesel exhaust emissions;
7. Main functions: Built-in printer, RS232 interface, configurable