SPECIAL PROXIMITY SWITCH PAGE1 PAGE2
Inductive proximity
switch (E2E series similar as Omron series)
¡ñDC 3 wire type (E2E-X¡õE¡õ)
¡¡
¡¡
Item |
M8 |
M12 |
M18 |
M30 |
|||||
Shield |
Non-shield |
Shield |
Non-shield |
Shield |
Non-shield |
Shield |
Non-shield |
||
E2E-1R5E¡õ |
E2E-X2ME¡õ |
E2E-X2E¡õ |
E2E-X5ME¡õ |
E2E-X5E¡õ |
E2E-X10ME¡õ |
E2E-X10E¡õ |
E2E-X18ME¡õ |
||
1.5mm¡À10% |
2mm¡À10% |
2mm¡À10% |
5mm¡À10% |
5mm¡À10% |
10mm¡À10% |
10mm¡À10% |
18mm¡À10% |
||
Voltage |
DC12~24V £¨P-P£©fluctuate at 10% less |
||||||||
Consumption |
13mA less |
||||||||
Standard detected object |
magnetic metal |
||||||||
standard detected object |
Iron 8¡Á8¡Á1mm |
Iron 12¡Á12¡Á1mm |
Iron 12¡Á12¡Á1mm |
Iron 15¡Á15¡Á1mm |
Iron 18¡Á18¡Á1mm |
Iron 30¡Á30¡Á1mm |
Iron 30¡Á30¡Á1mm |
Iron 54¡Á54¡Á1mm |
|
tolerance distance |
10% of detection distance less |
||||||||
tolerance frequency *3 |
2.0kHz |
0.8kHz |
1.5kHz |
0.4kHz |
0.6kHz |
0.2kHz |
0.4kHz |
0.1kHz |
|
output control (switch capacity)*2 |
max 200mA |
||||||||
influence of temperature |
within 10% of detection distance at +23 C in the range of -25~+70 C |
||||||||
influence of voltage |
¡À15% / ¡À1% |
||||||||
residual voltage |
(Load current of 200 mA and 2 m long conductor) |
||||||||
insulation resistance |
between the main body and crust of charger |
||||||||
|
Crust |
Cuzn |
PBT |
||||||
detection surface |
¡ñAC 2 wire type
Dimension Detecting distance
¡¡ Output
¡¡ Item NO.
¡¡ Shield
M8 1.5mm NO
¡¡ E2E-X1R5Y1
¡¡ M12 2mm NOE2E-X2Y1¡¡*1.2 NC E2E-X2Y2 M18 5mm NOE2E-X5Y1¡¡*1.2 NC E2E-X5Y2 M30 10mm NOE2E-X10Y1¡¡*1.2 NC E2E-X10Y2 ¡¡ M8 2mm NO
¡¡ E2E-X2MY1
M12 5mm NOE2E-X5MY1¡¡*1.2 NC E2E-X5MY2
M18
10mm NOE2E-X10MY1¡¡*1 NC E2E-X10MY2 M30 18mm NOE2E-X18MY1¡¡*1 NC E2E-X18MY2
Inductive proximity switch (similar as Autonics series)
¡¡
Type |
DC 3 wire switching type |
|||||||
Flush |
Non-flush |
Flush |
Non-flush |
Flush |
Non-flush |
Flush |
Non-flush |
|
Model |
PR08-1.5DN |
PR08-2DN |
PR12-2DN |
PR12-4DN |
PR18-5DN |
PR18-8DN |
PR30-10DN |
PR30-15DN |
Appearances |
|
|
|
|
||||
Detecting distance |
1.5mm¡À10% |
2mm¡À10% |
2mm¡À10% |
4mm¡À10% |
5mm¡À10% |
8mm¡À10% |
10mm¡À10% |
15mm¡À10% |
Hysteresis |
Max.10% of detecting distance |
|||||||
Standard target |
8¡Á8¡Á1mm( iron) |
12¡Á12¡Á1mm( iron) |
18¡Á18¡Á1mm( iron) |
25¡Á25¡Á1mm(lron) |
30¡Á30¡Á1mm(lron) |
45¡Á45¡Á1mm(lron) |
||
Setting distance |
0 to 1.05mm |
0 to 1.4mm |
0 to 2.8mm |
0 to 3.5mm |
0 to 5.6mm |
0 to7mm |
0 to10.5mm |
|
Power supply |
DC12-240V |
|||||||
Current consumption |
Max.10mA |
|||||||
Response frequency |
800Hz |
400Hz |
350Hz |
200Hz |
250Hz |
100Hz |
||
Residual voltage |
Max.2V |
Max.1.5V |
||||||
Control output |
200mA |
|||||||
Protection circuit |
Reverse polarity protection,surge protection circuit,overload & short-circuit protection except PR08,12 series |
|||||||
Protection |
IP67(IEC Standard) |
¡¡
Type |
AC 2 wire switching type |
|||||
Flush |
Non-flush |
Flush |
Non-flush |
Flush |
Non-flush |
|
Model |
PR12-2AO |
PR12-4AO |
PR18-5AO |
PR18-8AO |
PR30-10AO |
PR30-15AO |
Appearances |
|
|
|
|||
Detecting distance |
2mm¡À10% |
4mm¡À10% |
5mm¡À10% |
8mm¡À10% |
10mm¡À10% |
15mm¡À10% |
Hysteresis |
Max.10% of detecting distance |
|||||
Standard target |
12¡Á12¡Á1mm(lron) |
18¡Á18¡Á1mm(iron) |
25¡Á25¡Á1mm(lron) |
30¡Á30¡Á1mm(lron) |
45¡Á45¡Á1mm(lron) |
|
Setting distance |
0 to 1.4mm |
0 to 2.8mm |
0 to 3.5mm |
0 to 5.6mm |
0 to 7mm |
0 to 10.5mm |
Power supply |
DC100-240V |
|||||
Current consumption |
Max.25mA |
|||||
Response frequency |
20Hz |
|||||
Residual voltage |
10VÒÔÏÂ Max.10V |
|||||
Control output |
150mA |
200mA |
||||
Protection circuit |
Surge protection circuit |
|||||
Protection |
IP67(IEC Standard) |
SPECIAL PROXIMITY SWITCH PAGE1 PAGE2