AC-DC TRIPLE OUTPUT

T-30 SERIES
¡¡
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter,minimum wave
  • ¡¡

    Model

    ¡¡
    Performance
    D-60A D-60B
    CH1 CH2 CH1 CH2
    DC output voltage 5V 12V 5V 24V
    Output voltage error(Note:2) ¡À2% ¡À6% ¡À2% ¡À5%
    Rated output current 46A 3A 3A 1.8A
    Output current rage 0.3-6A 0.2-4A 0.3-6A 0.2-2.2A
    Wave and noise(Note:3) 75mVp-p 150mVp-p 75mVp-p 150mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À1% ¡À0.5% ¡À0.5%
    Load stability(Note:5) ¡À0.5% ¡À4% ¡À0.5% ¡À4%
    DC output power 56W 58W
    Efficiency 73% 76%
    Adjustable range for DC voltage CH1+10,-5% CH1+10,-5%
    Range for input voltage 85~264VAC 47~63Hz;120-370VDC
    Input current 2A/115V 1A/230V
    Impact current Cool-start current 30A/115V 60A/230V
    Leakage current <1A/240VAC
    Overload protection 105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:Current limit reset:self-reset
    Over-voltage protection ¡­¡­
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ) ON+5V OUTPUT
    Start,rise and lock time 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60·Ö,minutes for each shaft
    Resistance to pressure Input and output internal:1.5KVAC, Input and enclosure:1.5KVAC, Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ 20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 159*97*38mm
    Weight 0.55Kgs
    Safety standard Meet UL1012 TUV(En55022) CLASS B, IEC801-2,3,4 IEC555-5
    EMC standard ¡­¡­
    Note:1.The testing condition for the parameter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%
    T-40 SERIES
    ¡¡
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter,minimum wave
  • ¡¡

    Model

    ¡¡
    Performance
    T-40A T-40B T-40C
    CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
    DC output voltage 5V 12V -5V 5V 12V -12V 5V 15V -15V
    Output voltage error(Note:2) ¡À2% ¡À6% ¡À8% ¡À2% ¡À6% ¡À8% ¡À2% ¡À6% ¡À8%
    Rated output current 3A 2A 0.5A 3A 2A 0.5A 3A 1.5A 0.5A
    Output current rage 0.6-5A 0.2-3A 0.1-1A 0.6-5A 0.2-3A 0.1-1A 0.6-5A 0.2-2A 0.1-1A
    Wave and noise(Note:3) 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À1% ¡À1% ¡À0.5% ¡À1% ¡À1% ¡À0.5% ¡À1% ¡À1%
    Load stability(Note:5) ¡À0.5% ¡À4% ¡À6% ¡À0.5% ¡À4% ¡À6% ¡À0.5% ¡À4% ¡À6%
    DC output power 41.5W 45W 45W
    Efficiency 72%/115VAC 72%/115VAC 72%115VAC
    Adjustable range for DC voltage CH1+10,-5% CH1+10,-5% CH1+10,-5%
    Range for input voltage 85~132VAC/170~264VAC Switch choice 47~63Hz;120~370VDC
    Input current 1.2A/115V 0.7A/230V
    Impact current Cool-start current 20A/115V 460A/230V
    Leakage current <3.5A/240VAC
    Overload protection 105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:current limit reset:self-reset
    Over-voltage protection CH1:5.75~6.75V
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ) ON+5V OUTPUT
    Start,rise and lock time 1.6s,50ms,16ms/115VAC 800ms,50ms,60ms/230VAC
    Vibration resistance 10~500Hz,2G 3AXES 10min/1cycle(1Hour/minutes for each shaft)
    Resistance to pressure Input and output internal:3KVAC, Input and enclosure:1.5KVAC, Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 129*98*38mm
    Weight 0.45Kgs
    Safety standard Meet UCSA INTERNATIONAL MARK(CSA950,UL1950,IEC950,EN60950)
    EMC standard Conform to CISPR22(EN5502,IEC801-2,3,4.IEC555-2
    Note:1.The testing condition for the parameter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%}
    ¡¡¡¡ 6.
    ¡¡¡¡ 7.C2,3,6 must be knocked down.
    T-50 SERIES
    ¡¡
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter,minimum wave
  • ¡¡

    Model

    ¡¡
    Performance
    T-50A T-50B T-50C T-50D
    CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
    DC output voltage 5V 12V -5V 5V 12V -12V 5V 15V -15V 5V 15V 24V
    Output voltage error(Note:2) ¡À2% ¡À5% ¡À5% ¡À2% ¡À5% ¡À5% ¡À2% ¡À5% ¡À5% ¡À2% ¡À6% ¡À6%
    Rated output current 7A 1A 1A 5A 1A 1A 4A 1A 1A 3A 1A 1A
    Output current rage 0.6-7A 0.2-1A 0.2-1A 0.6-5A 0.2-1A 0.2-1A 0.6-4A 0.2-1A 0.2-1A 0.6-4A 0.2-2A 0.2-1A
    Wave and noise(Note:3) 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 50mV 120mV 120mV
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.5 ¡À0.5% ¡À0.5% ¡À0.5 ¡À0.5% ¡À0.5% ¡À0.5 ¡À0.5% ¡À1% ¡À1%
    Load stability(Note:5) ¡À1% ¡À4% ¡À4% ¡À1% ¡À4% ¡À4% ¡À1% ¡À4% ¡À4% ¡À1% ¡À5 ¡À5%
    DC output power 52W 49W 50W 51W
    Efficiency 66% 69% 71% 72%
    Adjustable range for DC voltage CH1+10,-5% CH1+10,-5% CH1+10,-5% CH1+10,-5%
    Range for input voltage 85~132VAC/170~264VAC Switch Choice 47~63Hz;240~370VDC
    Input current 1.6A/115V 0.8A/230V
    Impact current Cool-start current 20A/115V 40A/230V
    Leakage current <0.5A/240VAC
    Overload protection 105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:current limit reset:self-reset
    Over-voltage protection ¡­¡­
    High-temperature protection  
    Temperature factor ¡À0.03%¡æ(0~50¡æ) ON+5V OUTPUT
    Start,rise and lock time 200ms,50ms,16ms
    Vibration resistance 10~500Hz,2G 3AXES 10min./1cycle,time:1 hour, minutes for each shaft
    Resistance to pressure Input and output internal:3KVAC, Input and enclosure:1.5KVAC, Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 159*97*38mm
    Weight 0.45Kgs
    Safety standard Meet UL1012
    EMC standard ......
    Note:1.The testing condition for the parameter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%}
    ¡¡¡¡ 6.
    T-60 SERIES
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter,minimum wave
  • Model

    ¡¡
    Performance
    T-60A T-60B T-60C
    CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
    DC output voltage 5V 12V -5V 5V 12V -12V 5V 15V -15V
    Output voltage error(Note:2) ¡À2% ¡À6% ¡À6% ¡À2% ¡À6% ¡À6% ¡À2% ¡À6% ¡À6%
    Rated output current 5A 2.5A 0.5A 5A 2.5A 0.5A 5A 2A 0.5A
    Output current rage 0.5-7A 0.2-3.5A 0-1A 0.5-7A 0.2-3.5A 0.1-1A 0.5-7A 0.2-3A 0-1A
    Wave and noise(Note:3) 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À1% ¡À0.5% ¡À0.5% ¡À1% ¡À0.5% ¡À0.5% ¡À1% ¡À0.5%
    Load stability(Note:5) ¡À1% ¡À4% ¡À1% ¡À1% ¡À4% ¡À1% ¡À1% ¡À4% ¡À1%
    DC output power 57.5W 61W 62.5W
    Efficiency 72% 72% 72%
    Adjustable range for DC voltage CH1+10,-5% CH1+10,-5% CH1+10,-5%
    Range for input voltage 85~264VAC 47~63Hz; 120~370VDC
    Input current 2A/115V 1A/230V
    Impact current 30A/115V 60A/230V
    Leakage current <1mA/240VAC
    Overload protection 105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:current limit reset:self-reset
    Over-voltage protection CH1:5.75~6.75V
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ) ON+5V OUTPUT
    Start,rise and lock time 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC
    Vibration resistance 10~500Hz,2G 3AXES 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure Input and output internal:3KVAC, Input and enclosure:1.5KVAC, Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 159*97*38mm
    Weight 0.56Kgs
    Safety standard Meet UL1950
    EMC standard Conform to IEC801-2,3,4,IEC555-2
    Note:1.The testing condition for the parameter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%}
    ¡¡¡¡ 6.
    ¡¡¡¡ 7.C2,3,6 must be knocked down.
    T-100 SERIES
    ¡¡
  • Low price and high reliability
  • 105¡æ output capacitor
    ¡¡
  • AC input power suitable for the world
    ¡¡
  • High efficiency and low operation temperature
    ¡¡
  • Soft-start current can reduce the AC input impact effectively
    ¡¡
  • With short-circuit and overload protection
    ¡¡
  • 100% full-load burning test
    ¡¡
  • Installed with EMI filter,minimum wave
  • ¡¡

    Model

    ¡¡
    Performance
    T-100A T-100B
    CH1 CH2 CH3 CH1 CH2 CH3
    DC output voltage 5V 15V -15V 5V 12V -24V
    Output voltage error(Note:2) ¡À2% ¡À6% ¡À6% ¡À2% ¡À6% ¡À6%
    Rated output current 10A 2.5A 1A 6A 2A 2A
    Output current rage 2-12A 0.2-2.5A 0.1-1A 2-12A 0.1-2A 0.2-2A
    Wave and noise(Note:3) 80mVp-p 150mVp-p 150mVp-p 80mVp-p 1500mVp-p 150mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À1% ¡À1% ¡À0.5% ¡À1% ¡À1%
    Load stability(Note:5) ¡À1% ¡À5% ¡À5% ¡À1% ¡À5% ¡À5%
    DC output power 100W 102W
    Efficiency 77% 79%
    Adjustable range for DC voltage CH1+10,-5% CH1+10,-5%
    Range for input voltage 85~132VAC/170~264VAC Switch choice 47~63Hz;240~370VDC
    Input current 2.5A/115V 1.25A/230V
    Impact current Cool-start 30A/115V 60A/230V
    Leakage current <0.5mA/240VAC
    Overload protection 105%~150% TYPE:FOLDBACK Reset:recycle AC ON/OFF
    Over-voltage protection ¡­¡­
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ) ON+5V OUTPUT
    Start,rise and lock time 200ms,50ms,16ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure Input and output internal:1.5KVAC, Input and enclosure:1.5KVAC, Output and enclosure:0.5KVAC
    Isolation resistance Input and output internal, input and enclosure, Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 199*110*50mm
    Weight 0.83Kgs
    Safety standard Conform UL1012 Requirement
    EMC standard ......
    Note:1.The testing condition for the parameter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%