TDS Meter, Conductivity Meter / Conductometer, EC Meter, CF Meter

 

TDS meter          EC/CF (conductivity), salinity meter          bench-top TDS/conductivity meter
 

bench-top conductivity meter

 

DDS-W SERIES MICROPROCESSOR CONDUCTIVITY METER

Single Point Push-Button Calibration:
DDS-W series with single point calibration function, you need only set conductivity value of the calibration solution at 25oC and immerse conductivity electrode into solution, then press [ENTER] key, the meter will calibrated automatically.
Auto-Ranging for Conductivity:
The meter with auto-ranging function when measure conductivity. After electrode immersed in solution, the meter will fast response and convert range.
Auto Temperature Compensation:
DDS-12DW will recognize the temperature sensor automatically and measure temperature after temperature sensor connected to the meter. If the conductivity electrode connected to it, the meter will

enter automatic temperature compensation.

Adjustable Temperature Coefficient:
Different ion solution usually have different temperature coefficient, setting temperature coefficient correctly is very important to measurement, DDS-W series can be set in the range of 0 to 3.9%per centigrade degree.

Adjustable Cell Constant:

When measuring higher or lower conductivity solution, you should choose conductivity electrode with

different constant. The meter with three cell constant (0.1,1,10) for your choice. 

What's included:

DJS-1 conductivity electrode(K=1), electrode holder, 9V power adapters, temperature probe (only for

DDS-12DW)

Model   DDS-11AW DDS-307W   DDS-12DW

   Conductivity Range

 

0~1.999, 19.99, 199.9,

1999uS/cm, 19.99, 199.9mS/cm

   Conductivity Accuracy   ±1.5% F.S ±1% F.S ±1% F.S
   Temperature Range   --- --- 0~100oC
   Temperature Accuracy   --- --- ±1oC
   Calibration Points   1 Point
   Calibration Solution   146.6uS/cm, 1408uS/cm, 12.85mS/cm
   Temperature Compensation   0~50oC, Manual 0~50oC, Manual 0~50oC, Manual or Automatic
   Temperature Coefficient   0~3.9%/oC
   Cell Constant   K=0.1, 1, 10, Adjustable
   Display   LCD
   Power Requirements   9VDC, using AC adapters 220VAC, 50Hz
   Dimensions   210(L)mm×205(W)mm×65(H)mm
    Weight   1.5kg
   

FEATURES:
:: Up to 5 points calibration (1 point per range)
:: Auto-ranging for conductivity
:: Automatic temperature compensation
:: Adjustable temperature coefficient (0 to 3.9%)
:: Adjustable cell constant (K=0.1, 1, 10)
:: Adjustable TDS coefficient
:: Automatic message prompts
:: Expanded memory stores and recalls 99 data sets
:: USB Communication interface can be sent data to
computer
METERS INCLUDED:

DJS-1 and DJS-10 Conductivity Electrode, Temperature

Probe, DC9V Power Adapters

 

 

PHS950 PRECISION  CONDUCTIVITY/TDS/SALINITY/RESISTIVITY METER

PHS950 meter is used for measuring conductivity, Total

Dissolved Solid (TDS), salinity, resistivity and temperature

in liquids.

SPECIFICATIONS:

 

Model   PHS950
    Conductivity Range   0~1.999, 19.99, 199.9, 1999uS/cm, 19.99, 199.9mS/cm
    Conductivity Accuracy   ±0.5% F.S
    TDS Range   0~Max.200ppt
    TDS Accuracy   ±1% F.S
    Salinity Range   0.00~5.00% (50ppt)
    Salinity Accuracy   ±0.05% (0.5ppt)
    Resistivity Range   0 to 100MΩ
    Resistivity Accuracy   ±1% F.S
    Temperature Range   0~100oC
    Temperature Accuracy   ±1oC
    Calibration Points   1 point per range  
    Temperature Compensation   0~50oC, Automatic or Manual
    Temperature Coefficient   0~3.9%/oC
    TDS Conversion Factor   0.01~1.00
    Cell Constant   K=0.1, 1, 10 (Adjustable)
    Memory and Output   99 data sets with Date/Time stamping, USB communication interface
    Display   6.5' LCD
    Power Requirements   DC9V, using AC adapters, 220VAC, 50Hz
    Dimensions   210(L)×188(W)×60(H)mm
    Weight   1.7kg
   

DDS-307 Conductivity Meter

Model

DDS-307

Range

0.001~2μS/cm

0.01~20μS/cm

0.1~200μS/cm

0.001~2ms/cm

0.01~20ms/cm

0.1~200mS/cm

Accuracy

±1% Full Scale

Power

DC9V 100mA

Operating Conditions

Temperature: 5~40ºC

Humidity: 90% maximum

Dimensions

208×200×76mm

Weight

390g

 

   

Optional accessories:

1. DJS-1 bright electrode

2. DJS-10 Conductivity electrode

3. DJS-0.1 Platinum electrode

4. DJS-0.01 Titanium alloy electrode

Overall dimension & weight:

Shipping package dimension: 332-265-275mm

Gross weight: 3kg Net weight: 2kg

DDSJK-307 Conductivity Meter
Characteristics:

1. 31/2LED display
2. With manual temperature compensation.
3. There are four types of electrodes for conduction cell constant: 0.01,0.1,1.0 and 10.0cm-1 ,user can select by your need.
4. Automatic switching measuring frequency, measuring ultrapure water with using K=0.01cm-1 titanium alloy electrode and sealing measuring cell
5. With 0~10mV output signal
Specifications:
1. Measurement range: 0-1×105 mS/cm
There is the best correspondence point between conductivity measuring range and conduction cell constant

conduction cell constant(cm-1 )

0.01

0.1

1

10

Measuring range (uS/cm)

0~2

0.2~20

2~1×104

1×104~1×105

2. Electrode constant, cm-1: 0.01. 0.1, 1.0.10.0
3. Accuracy of the electric unit: ±0.5%(FS) ±1 bit
4. Stability of the electronic unit: ±0.33%(FS) ±1bit/3h
5. Accuracy ±1.0%(FS) ±1 bit
6. The range of temperature compensation: 15-35ºC, basic temperature: 25ºC

Standard configuration:

1. Main instrument 1
2. Power cable 1
3. Platinum-black Electrode DJS-1C 1
4. Multi-function Electrode support stand 1
   

DDSJK-307A Conductivity/TDS/ºC Meter

Functions:

Large screen and LCD segmented display

It functions as automatic and manual temperature compensation.

If matched with the titanium alloy sensor of 0.01cm-1  and sealed measuring reservoir, it can test high purity water.

It is equipped with DJS-1C conductancesensor(platinum black) and T-818-B-6 temperaturesensor.

   Specifications:

1, Measuring range:

Conductivity: 0.00μS/cm~100μS/cm

         TDS: 0~1000 mg/L

Temperature: 0.0~60.0 ºC
      2, Accuracy:

         Conductivity: ±0.5%FS

         T D S: ±1.0%FS)        

Temperature: ±0.3ºC±1 bit
      3
,
Stability: (±0.33%FS±1 digital) /3h
      4
, Temperature compensation range: Manual/Automatic (0.0~40.0)
ºC

      5, Temperature compensation coefficient: 2%

      6, Power supply:: AC(220±22)V; (50±l)Hz

      7, Dimension(mm): 300×200×72

      8, Weight: 1.5kg

9, Case outside serial No: WXS-A008-1

Conductance Constant and corresponding Conductivity measuring range

Electrodeconstant (K) (cm-1) 0.01 0.1 1 10
Measuring range(μS/cm) 0.0~2.0 0.2~20.0 2~1×104 1×104~1×105
   

Standard configuration:

1. Main instrument

1

2. Power cable

1

3. DJS-1C Platinum-black Electrode

1

4. T-818-B-6 Temperature Sensor

1

5. REX-I Multi-function Electrode support stand

1

6. Data Collecting software

1

7. RS-232 Communication Line

1

8. TP-16 Print Connection Line

1

Optional accessories:

1. DJS-1 bright electrode

2. DJS-10 Conductivity electrode

3. DJS-0.1 Platinum electrode

4. DJS-0.01 Titanium alloy electrode

Overall dimension & weight:

Shipping package dimension: 332-265-275mm

Gross weight: 3kg Net weight: 2kg

DDSJ-308A  Conductivity/TDS/Salinity/Temp Meter

Characteristics:
1. Double digits LCD display with big screen and blue back light, display conductivity value and temperature value
2. It can be used to measure conductivity, TDS, salinity and temperature.
3. Automatic temperature compensation, automatic calibration, automatic range changing and electricity cutting off protection
4. Measurement results can be stored, deleted, consulted and printed. It can store at most 50 sets of measurement data.
5. With RS-232 interface, Model TP-16 printer can be connected
6. With calibration function, can set electrode constant and TDS switching coefficient
7. Measuring ultrapure water with using K=0.01cm-1 titanium alloy electrode and sealing measuring cell
8. Connecting PC with the meter with selecting data soft
Specifications:
1. Measurement range:
Conductivity: 0-1.999´105 uS/cm(be divided into six ranges and can range changing automatically)
0-1.999 uS/cm 2.00-19.99 uS/cm 20.0-199.9 uS/cm
200-1999 uS/cm 2.00-19.99 mS/cm 20.0-199.9 mS/cm
TDS: 0-19900 mg/L (be divided into five ranges and can range changing automatically)
0-10.00 mg/L 10.0-100.0 mg/L 100-1000 mg/L
1.00-10.00 g/L 10.0-19.99 g/L
Salinity: 0.0-80 ppt〔(0.0-8.00)%〕
Temperature: -5-105ºC
2. Electrode constant, cm-1:0.01. 0.1, 1.0.10.0
3. Accuracy of the electronic unit: Conductivity: ±0.5%(FS) ±1bit
Salinity: ±1.0ppt
Temperature: ±0.3ºC ±1.bit
4. Stability of the electronic unit: ±0.33%(FS) ±1bit/3h
5. Accuracy: ±0.75%(FS) ±1 bit
6. The range of temperature compensation: 0-50ºC

   

Standard Configuration

Order No

Product Name and Specification

Quantity

1.

SRSJ-318 conductivity meter

1

2.

Platinum black electrode(K=1)

1

3.

Temperature sensor

1

4.

Multifunctional electrode holder

1

5.

Power source(9VDC,800mA,inside-positive and outside-negative)

1

 

Optional Accessories

Order No

Product Name and Specification

Quantity

1.

Bright electrode(K=1)

1

2.

Conductivity electrode(K=10)

1

3.

Platinum electrode(K=0.1)

1

4.

Titanium alloy electrode(K=0.01)

1

 

Functions:
1. It can measure conductivity, resistivity. TDS(total dissolved solids), salinity and temperature of the current solution.
2. It applies microprocessor-based technology and functions as automatic temperature compensation, auto-calibration, auto measuring range switch.
3. The user can calibrate the electrode constant or TDS conversion coefficient. Also, the instrument supports two-point calibration.
4. 5.7 inch large touch screen, friendly English language interface for easy use
5. It follows GLP practice
6. The stored data can be displayed by graphics and can be viewed, printed and deleted.
7. It allows the user to review current measuring date and the last calibration data.
8. It contains 3 kinds of measuring modes: Continuous measurement, timed measurement and balance measurement which can meet different measuring requirements.
9. It has RS-232 interface and USB. If matched with data collecting software, it can be communicated with PC.

SRSJ-318 Conductivity Meter (touch screen)

 

SPECIFICATION:

        Model

Specifications

SRSJ-318

Parameters

Conductivity/Resistivity/TDS/Salinity/°C

Range

 

Conductivity

0.055μS/cm~199.9mS/cm

( full range measuring, no need to exchange electrode)

Resistivity

5.00Ω·cm~18.25MΩ·cm

TDS

0.000 mg/L~100g/L

Salinity

(0.00~8.00)%

Temperature

-5.0~135.0°C

Resolution

Conductivity

0.001μS/cm

Resistivity

0.01Ω·cm

TDS

0.001 mg/L

Salinity

0.01%

Temperature

0.1°C

Accuracy

Conductivity

±0.5%FS

Resistivity

±0.5%FS

TDS

±0.5%FS

Salinity

±0.1%

Temperature

±0.3°C

Temp compensation

Manual/Auto (-5.0~135.0) °C

Temp coefficient

Adjustable

Calibration

May calibrate electrode constant or TDS switch coefficient.

support two-point calibration

Measuring mode

3 (continuous measurement, timed measurement and balance measuring mode)

Data storage

1500 data with time-and-date for GLP compliance (to display measuring result in diagram directly)

View, delete and print

Yes

Display

Touch, big LCD screen

Output

RS-232, USB

Software

1.1DC

Power

Universal power adapter (9V DC, 800mA, inside - positive, outside - negative)

Case outside serial No.

WXS-A009-1

Dimension (mm), Weight(kg)

250*195*100, 2

Gross Weight(kg)

4

Packing Size (mm)

(Carton Box)

370*310*340

   

SR513 Lab Conductivity Meter (5 in 1)

Features and Applications:

- Be used for conductivity measuring of general water solution

- Plastic conductivity electrode with ATC, easy to use

- Economical bench-top conductivity meter

- Nice appearance, easy to use. It equips a flexible electrode holder, intelligent stirrer and a brief operation manual.

- Meter meets with the requirement of international GLP standards. It features up to automatic calibration, automatic temperature compensation, storage data, clock display, time measurement, RS232 output, functions setting and self-diagnose information etc.

- It adopts digital filter and step slipping technology to improve meter's response speed and repeatability.

- Meter has the only product serial number.

Dustproof and waterproof meter meets IP54 standards.

Measuring Parameters:

Conductivity, resistivity, TDS, salinity and temperature

Range:

Cond:0 to 200 mS/cm,be divided into five ranges

(0.00 to 20.00)μS/cm; (20.0 to 200.0)μS/cm;

(200 to 2000)μS/cm; (2.00 to 20.00)mS/cm;

(20.0 to 200.0)mS/cm

Res: (0 to 100)MΩ·cm; TDS: (0 to 100)g/L

Sal: (0 to 100)ppt    Temp: (-10 to 110)ºC

Accuracy:

Cond: ±1.0% full scale       Temp: ±0.5ºC

Other Parameters:

ATC: (0 to 50)ºC Storage

Data: 100 groups;

Communication Connector: RS-232;

Power: DC9V/300mA;  

Size & Weight: (160×190×70)mm/880g

Accessories:

1. 2301-M plastic conductivity electrode (K=1,ATC)

2. Model 602 flexible electrode holder

3. RS-232 communication software

 

Model: SR515 Precision Conductivity Meter

Measuring Parameters: Conductivity, Resistivity, TDS, salinity and temperature

Features and Applications

- High precision bench-top conductivity meter

- “CH” and “USA” two series of standard solution can be setup, automatically recognizes eight kinds of conductivity

- Calibration solution.

- 18 ºC, 20 and 25 three kinds of reference ºC temperature can be setup.

- Inside setup with function of high purified water non-linearity automatic temperature compensation, suitable for accurate conductivity measurement for high purified water.

Specifications:

Range:  

Cond: 0 to 2000 mS/cm,be divided into five ranges

(0.00 to 20.00)μS/cm; (20.0 to 200.0)μS/cm;  

(200 to 2000)μS/cm; (2.00 to 20.00)mS/cm;  

(20.0 to 200.0)mS/cm;  (200 to 2000)mS/cm (k=10)

Res: (0 to 100)MΩ·cm; TDS: (0 to 100)g/L

Sal: (0 to 100)ppt  Temp: (-10 to 110) ºC  

Accuracy:  

Cond: ±0.5% full scale   

Temp: ±0.4 ºC

Other Parameters: 

ATC: (0 to 50) ºC Storage

Data: 600 groups; 

Communication Connector: RS-232; 

Power: DC9V/300mA; 

Size & Weight: (160×190×70)mm/880g

What's included: 

1. 2401-M conductivity electrode (K=1,ATC)

2. Model 602 flexible electrode holder

3. RS-232 communication software

 

TDS meter          EC/CF (conductivity), salinity meter          bench-top TDS/conductivity meter